Because the crimp terminal of 3.5 sq is out of JIS standard. The 5.5 sq crimp terminal can also fix the 3.5 sq cable. More Details >>
- No:20852
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Frequency setting by the CC-Link
When the frequency setting value is written by the CC-Link to EEPROM, the frequency setting value set with the PU (operation panel) is changed. More Details >>
- No:20851
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
1. As the measurement condition is unknown, the possible cases are as follows: - If you measured the current on the input side of the inverter, since the cu... More Details >>
- No:21457
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Shielded wiring of external speed setting potentiometer
Grounding can often get dirty due to influence from the inverter main circuit switching. Therefore, when the potentiometer shielded wire is connected to the ... More Details >>
- No:21455
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Since the heat sink and fan are not waterproof, you need to enclose them so that they are not exposed to the spray of water. If you use the inverter (heat si... More Details >>
- No:21433
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Although you can connect an analog or digital indicator to the terminal FM, use an analog indicator since the wiring length is long. (The maximum wiring leng... More Details >>
- No:21415
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasure against the harmful effect on model selection and other devices
Harmful elements that may affect other devices through the input side of the inverter include noise and harmonics. Harmonics can be reduced by inserting the ... More Details >>
- No:21396
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The instantaneous power failure error occurs when the power is turned ON instantaneously (within 100 ms) after the power is turned OFF. When the motor is coa... More Details >>
- No:21388
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
The signal becomes 0 when the RES signal is turned ON. More Details >>
- No:21238
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL