You can do it by using the optional DIN rail attachment (FR-DU01/02). More Details >>
- No:21598
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-U100
-
When controlling motor with brake by inverter
Use the RUN signal to turn ON and OFF the brake.Using the MRS (output shutoff) signal to turn ON the brake shuts off the inverter's output and reduces influe... More Details >>
- No:21960
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Imbalanced input side power supply
1. Power supply voltage phase imbalance toleranceMitsubishi inverter's input power supply voltage phase imbalance tolerance is ±3%.If the phase imbalance exc... More Details >>
- No:21987
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Current value monitor indicator
The measurable frequency range and measurement precision of the inverter's output current greatly differ depending on the measurement instrument.Check with t... More Details >>
- No:22079
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Operation at external operation/stop
It is recommended to turn OFF the start signals (STF and STR) when stopping the inverter.In this case, it is not probable that the motor rotates due to a cal... More Details >>
- No:22102
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-E500
-
No, you cannot use the safety stop function. More Details >>
- No:20817
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-B
-
The count is resumed from 0. Thus, the times of the overflow is reset. More Details >>
- No:20902
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Output current: Because the filter, effective value of the output current displayed on the operation panel, is included, the momentary fluctuation is difficu... More Details >>
- No:20919
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Yes, it is. However, it is not suitable for the low speed regenerative side. It is also recommended to use a dedicated control for winding/unwinding applicat... More Details >>
- No:20928
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Using a motor dedicated to the direct connection (with a creep-free bearing) may result in a bearing noise. More Details >>
- No:20963
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others