When Pr.80 and Pr.81 are set to the value other than "9999", control other than V/F control is performed. For the FR-F700(P) FR-D700, and FR-F700PJ, Pr.81 is... More Details >>
- No:21259
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
The 75K or higher DC reactor is included in the 75K or higher inverter. The option cannot be purchased separately. More Details >>
- No:21252
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Communication EEPROM write selection (Pr.342)
They are cleared by the RES signal from the external terminals or inverter reset from the communication. More Details >>
- No:21221
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Data with different capacity can be imported. Data with different voltage or model cannot be imported. More Details >>
- No:21196
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is one of other communication errors. The communication is not established. Check the communication settings. More Details >>
- No:21176
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
The following reasons are possible. - The signal of Z phase does not exist. (It is not returned normally.) - The setting of Pr.359 encoder rotation direction... More Details >>
- No:21162
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
The sine wave filter can be applied only under V/F control. When Pr.72 PWM frequency selection is set to 25, V/F control is set automatically. The applicable... More Details >>
- No:21068
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options , FREQROL-A800 , FREQROL-A700
-
SD1148 can turn ON multiple bits such as STF and RH simultaneously. SM turns ON bits individually. When SD1148 is H5, it is same as when SM1200 (STF) and SM1... More Details >>
- No:21057
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
The function is only for overheat protection. It does not affect the torque accuracy. More Details >>
- No:21040
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Communication specifications for connection of multiple inverters
Use the RS485 terminal for the multiple communication of the A series/F series inverters.* Communication with the PU connector is only one-to-one connection. More Details >>
- No:20998
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800