FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
Save the parameter file (.rpm) after reading the system file (.mel) created in SW1. With the saved parameter file (.rpm), the parameter of the 700 series can... More Details >>
- No:21141
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
At power-ON, the signal turns ON for a moment to perform a converter initial reset. More Details >>
- No:21156
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Install the resistor between the terminals PC and OH. More Details >>
- No:21160
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
Data with different capacity can be imported. Data with different voltage or model cannot be imported. More Details >>
- No:21196
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
They are cleared as well. More Details >>
- No:21207
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
Other than "0" can be input. The inverter is reset by writing any numerical value. More Details >>
- No:21224
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Checking bit state by CC-Link communication
Because the H0F monitor only observes the ON/OFF of the hardware, it cannot be checked. More Details >>
- No:21230
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
PID control of CC-Link communication
When performing the PID control by CC-Link communication, the X14 signal is disabled. More Details >>
- No:21233
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
The signal becomes 0 when the RES signal is turned ON. More Details >>
- No:21238
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
211-220 of Total 1306