FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
No, it cannot be connected to the RS-485 terminal. The 485 terminal supports the Mitsubishi protocol and Modbus-RTU, but it does not support the PU protocol.... More Details >>
- No:21037
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It is not output in the JOG operation mode. More Details >>
- No:21214
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Installing reactor for suppressing harmonics
You can connect multiple inverters to a single reactor. In this case, the load seems to be light from the reactor unless all of the inverters are rotating an... More Details >>
- No:21410
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Load current limit of inverter
You can input current from the terminal AM of the inverter to the programmable controller (for A/D conversion) and control the speed with the software of the... More Details >>
- No:21419
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Countermeasure against inverter noise
You can attach the following filters to the inverter input side:- Line noise filter (FR-BLF, FR-BSF01)- Radio noise filter (FR-BIF) While it is a good idea ... More Details >>
- No:21528
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
How many inverters can be connected?
Up to 32 units can be connected. (This is because the inverter communication conforms to RS-485.) More Details >>
- No:21589
- Release Date:2018/08/22 16:28
- Category: Engineering Software
-
Short-circuiting frequency setting terminals
You can short-circuit the terminals 10 and 2.If you are considering to perform operation at the maximum frequency, consider using the high-speed command RH o... More Details >>
- No:21951
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Surge voltage of 400 V inverter
1. Since the voltage resistance of the standard motor is not improved, it is recommended to use an "insulation-enhanced motor".If you are using an insulation... More Details >>
- No:21957
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Others
-
Using existing potentiometer by replacing inverter
It is OK if the resistance value of the speed varying potentiometer's resistance is 2 kΩ.Use the speed varying potentiometers used with the existing inverter... More Details >>
- No:21962
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Inverter 200 V input and 400 V output
We do not have an inverter that directly takes 200 V input and generates 440 V output. Therefore, as you mention, use a 400 V class inverter by boosting the ... More Details >>