Common connection of the terminal SD
There is no problem for only the terminal SD connection because undesirable current will not be flown. More Details >>
- No:21379
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasure against harmonics
When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>
- No:21398
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Although you can connect an analog or digital indicator to the terminal FM, use an analog indicator since the wiring length is long. (The maximum wiring leng... More Details >>
- No:21415
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
You can use an inverter for fan and pump with the compressor, but it is not recommended for an application that the motor load rapidly increases. More Details >>
- No:21443
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A100
-
1. As the measurement condition is unknown, the possible cases are as follows: - If you measured the current on the input side of the inverter, since the cu... More Details >>
- No:21457
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Items controllable via CC-Link
1. Not all items can be controlled. - Functions that cannot be controlled JOG, AU, CS, OH, X10, X11, X12, and X16 functions (Other functions can be control... More Details >>
- No:21459
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
I want to shorten deceleration time of small capacity motor
You can use an inverter with a larger capacity than the motor. You cannot connect a brake resistor to the FR-E520-0.1K and 0.2K. With the FR-E520-0.1K or 0.2... More Details >>
- No:21463
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Since the inverter power supply uses the single-phase input, you cannot use a 0.75K inverter with a 0.6 kW motor to draw the maximum ability of the motor. To... More Details >>
- No:21470
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>