It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>
- No:21416
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>
- No:21490
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
The 0.75 kW inverter with the single-phase 100 V power supply can be manufactured and is actually commercialized as the FR-U100 series. Manufacturing of the ... More Details >>
- No:21509
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
We do not offer a geared motor. More Details >>
- No:21647
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
We offer the following: <<Dedicated motor model variation>>- With standard legs (SF-VR__)5.5 kW, 7.5 kW, 11 kW, 15 kW, 18.5 kW, 22 kW, 30 kW, 37 ... More Details >>
- No:21649
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
The new function includes:- PI control function- Cumulative energy monitor (monitor accuracy: approximately ±25% of full scale value)- Response current limit... More Details >>
- No:21660
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A100
-
The terminal MRS assignment parameter is Pr.183. Set Pr.183 to "4" (AU). (This setting is for the E700.) More Details >>
- No:21850
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
You can install only one option card.If you want to use two types of cards, replace the inverter with the FR-A700 series.If you can use RS485 communication i... More Details >>
- No:21894
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700