The amount of heat generated by the FR-E500 series inverter is registered in the Mitsubishi Electric FA Global Website Member's page. Refer to the technical ... More Details >>
- No:21382
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Is the number of writing times of the parameter memory limited?
1. The limit of the parameter writing is 100,000 times. 2. Parameter error occurs. Since the data in the ROM may be broken, the inverter may become unavailab... More Details >>
- No:21385
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The operating environment of FA products
The following surrounding environment is common to all models. Surrounding air temperature: No problem. The inverters can be used in -10 to 50°C. Above sea l... More Details >>
- No:21386
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The instantaneous power failure error occurs when the power is turned ON instantaneously (within 100 ms) after the power is turned OFF. When the motor is coa... More Details >>
- No:21388
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Selection method of the reactor
For the use of the 400 V class inverter, the surge voltage suppression filter FR-ASF is provided to suppress the surge voltage occurred at the motor terminal... More Details >>
- No:21389
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Countermeasures when input power supply is turned off upon equipment fault
1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>
- No:21390
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
Functions available when using inverter on CC-Link
You can use the regular terminal block wire functions during CC-Link operation. Set Pr.338 (Operation command source) and Pr.339 (Speed command source) to e... More Details >>
- No:21393
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The FR-E540 uses common input for the control power supply and main circuit power supply. (It has only one power supply input terminal.) Therefore, you canno... More Details >>
- No:21395
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasure against the harmful effect on model selection and other devices
Harmful elements that may affect other devices through the input side of the inverter include noise and harmonics. Harmonics can be reduced by inserting the ... More Details >>
- No:21396
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Providing thermal protection is better for your safety. When the brake transistor explodes, the brake transistor alarm (E.BE) is output. Consider a counterme... More Details >>
- No:21397
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024