The function is only for overheat protection. It does not affect the torque accuracy. More Details >>
- No:21040
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It is not output in the JOG operation mode. More Details >>
- No:21214
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
There is a 10 ms delay after the inverter recognizes the start command (STF OR STR) before it starts decelerating. The delay is 10 ms. A delay of 100 ms is i... More Details >>
- No:21445
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
1. As the measurement condition is unknown, the possible cases are as follows: - If you measured the current on the input side of the inverter, since the cu... More Details >>
- No:21457
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Direct driven start by power supply
The warning "Do not use a magnetic contactor on the inverter input for frequent starting/stopping of the inverter." is indicated in the precautions at the be... More Details >>
- No:21458
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Connecting voltmeter to terminal AM
You can connect them in parallel. Connect the voltmeters in parallel, paying attention to the following: - The output current should not exceed the permissib... More Details >>
- No:21464
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Installing magnetic contactor on input side of inverter
Basically, there is no difference between the A200 and A500. For safer use, from the A500, it is recommended to completely shut off the power supply by turni... More Details >>
- No:21466
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
1. The inverter display is based on the frequency, and the speed and moving speed are displayed by converting the frequency into the corresponding value. The... More Details >>
- No:21480
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500