By attaching the optional card and dedicated cover, the depth increases by approximately 15 mm for the FR-E700, and approximately 22 mm for the FR-E700-SC.Si... More Details >>
- No:21835
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
Set Pr.550 (NET mode operation command source selection) to "2" (PU connector is the command source).When operating the inverter using the USB connector, set... More Details >>
- No:21904
- Release Date:2018/08/22 16:30
- Category: FREQROL-E700
-
Electronic thermal O/L relay setting
Set Pr.9 to the rated current at 50 Hz or a value 1.1 times as the rated current at 60 Hz.You can specify the motor type with Pr.71 (Applied motor). For a co... More Details >>
- No:21941
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
How can I have the motor coast to stop?
You can use the following two methods:1. Turn ON MRS at the same time when STF turns OFF.2. Set Pr.10 = 60 Hz, Pr.11 = 0 sec, and Pr.12 = 0% (when the invert... More Details >>
- No:21967
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Fault contact when connecting separate power supply for each control circuit
Since the inverter's fault contact is an NC contact, it does not open unless a fault occurs.Therefore, when the control power supply (and main circuit power ... More Details >>
- No:22035
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Notes when inverter capacity is larger than motor capacity
When using one-rank-higher inverter, as you mention, you need to care about the setting of the electronic thermal O/L relay.Setting the electronic thermal O/... More Details >>
- No:22040
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Can I set the FR-F series parameters?
The FREQROL-F500 series has been already supported by the setup software released since February 2000. More Details >>
- No:22068
- Release Date:2018/08/22 16:30
- Category: Engineering Software
-
1. By changing RWw1 while RYD is ON, you can change the inverter's frequency.You cannot do this with RYE. You need to turn OFF and then ON RYE each time you ... More Details >>
- No:22083
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Operation panel extension cable
Yes, you can use the 10BASE-T cable (straight) with the E500. More Details >>
- No:22085
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Square wave input is not recommended since it can cause failures (for example, damage the diode bridge). More Details >>
- No:22106
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-E500
291-300 of Total 1292