FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
The MM-BF and MM-CF are not compliant. The MM-GKR is compliant with the UL standard. More Details >>
- No:21005
- Release Date:2018/08/22 16:25
- Category: Magnet motor drive
-
Since the lower limit has been internally set, the setting value of 3 % or less is recognized as 3%. More Details >>
- No:20976
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Angular velocity change control
The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>
- No:22086
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-V200
-
Installation method of AM-5 terminal ammeter
The AM-5 output is 0 to 10 VDC voltage output.Therefore, you need to install a voltmeter.Also, since the inverter output current is displayed, the scale of t... More Details >>
- No:22016
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
1. You can reset the inverter from an external terminal.You can do it without regard to the setting of Pr.338 (Communication operation command source) and Pr... More Details >>
- No:21837
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Set Pr.79 to "2" (external operation mode). More Details >>
- No:21818
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
This is because the protective function works to stop the motor. It is not a fault indication.To cancel the protective function, turn OFF the start signal an... More Details >>
- No:21775
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
10 VDC voltage from terminal 10
Setting Pr.73 to "0" does not generate 10 VDC output.The inverter itself only has 5 V at the terminal 10.Setting this parameter to "0" allows 10 V input betw... More Details >>
- No:21727
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
SW1DND-FRC2 (FR Configurator2)
Check the setting value of Pr.414 (PLC function operation selection) and if the initial value: 0 (PLC function disabled) is set, set "1" or "2" and enable th... More Details >>
- No:21080
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software , FREQROL-A800 , FREQROL-F800
-
A tension sensor such as a dancer roll is required for speed control. Because an actual line speed input is required for the winding diameter calculation by ... More Details >>
- No:20926
- Release Date:2018/08/22 16:25