FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
You cannot use the brake unit FR-BU2 with the FR-E740-1.5K. To use the brake unit, increase the inverter capacity to 2.2K. You can use the brake unit with th... More Details >>
- No:21665
- Release Date:2018/08/22 16:28
- Category: FREQROL-E700
-
A motor overheats (the current increases) when the load is heavy.When the electronic thermal O/L relay works, you need to mitigate the load.If the current is... More Details >>
- No:22042
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Not required. Select it according to the capacity of the vector motor used. More Details >>
- No:20804
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>
- No:20812
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
It is for the HIV cable. More Details >>
- No:20850
- Release Date:2018/08/22 16:24
- Category: Options
-
The inverter is reset. More Details >>
- No:20869
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-E700
-
It is not possible because the RS-485 terminal block is not installed. Use the FR-A800 (RS-485 communication type) when performing the RS-485 communication. More Details >>
- No:20881
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes, the current is limited under the PM sensorless control. More Details >>
- No:20936
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
Because the internal reset processing is performed when the power supply is turned OFF, the fault state cannot be held. The details of the faults are saved i... More Details >>
- No:20942
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
351-360 of Total 1306