FAQ
FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
When controlling motor with brake by inverter
Use the RUN signal to turn ON and OFF the brake.Using the MRS (output shutoff) signal to turn ON the brake shuts off the inverter's output and reduces influe... More Details >>
- No:21960
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
AC reactor and line noise filter wiring
Basically, either is OK.Both orders are electrically identical, but "1" is recommended since it is preferable to place the line noise filter close to the inv... More Details >>
- No:21964
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Fault output terminal load pattern
The fault output terminals A and C, and B and C of the power regeneration converter FR-RC are not capable of a micro load of 5 VDC±5%, 10 mA. The minimum loa... More Details >>
- No:21966
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
The rotation ripple data for 1.5 kW is shown below.Drive unit: MD-CX520-1.5KMotor: MM-CF152Load: None (motor alone), carrier frequency: 2 kHz, wiring length:... More Details >>
- No:21968
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Can I use a brake resistor with the FR-S500?
The brake unit and its resistor FR-S520-0.4K to 3.7K are available.Mitsubishi Electric FA Global Website also explains so.(Note that the GZG GRZG discharging... More Details >>
- No:21970
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
They are capable of a load of 5 VDC±5% and 10 mA. More Details >>
- No:21977
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
We do not provide such plug-in optional cards. More Details >>
- No:21981
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
If the parameters related to the output voltage are not changed from the initial setting, it is unlikely that the output current at 55 Hz and 60 Hz is double... More Details >>
- No:21983
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
1. Can I set the frequency by the external potentiometer when multi-speed signal is 0 (nothing is input)?-> It is possible by using the external operation... More Details >>
- No:21990
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Availability of parameter unit
You cannot use the FR-PU04 with the FR-HC. More Details >>
- No:22005
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options