The operation panel of the FR-S500 is not detachable.For the FR-S500-○○K-R (compatible with RS-485 communication), you can install the FR-PU04 on the enclosu... More Details >>
- No:22058
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
General-purpose magnetic flux vector control is effective at low speed under a heavy load.To shorten the acceleration time, use Pr.44 to set the second accel... More Details >>
- No:22059
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Reset command during operation
The reset signal does not damage the inverter.It seems that the inverter went faulty due to other reasons.Mitsubishi Electric FA Center can inspect the inver... More Details >>
- No:22065
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
All parameters returned to initial values
The parameters of the A500 series are stored in the EEPROM.The reason why all parameters returned to the initial values is considered that you may have opera... More Details >>
- No:22066
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>
- No:22072
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
When consuming the regenerative power with the brake resistor, the brake transistor is triggered at a certain voltage to make the brake resistor use the rege... More Details >>
- No:22074
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Switching between high speed and low speed
As you mention, when the inverter is operated only with STF without inputting the speed command signal, the minimum frequency must be set to 10 Hz.However, a... More Details >>
- No:22078
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
1. By changing RWw1 while RYD is ON, you can change the inverter's frequency.You cannot do this with RYE. You need to turn OFF and then ON RYE each time you ... More Details >>
- No:22083
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Operation panel extension cable
Yes, you can use the 10BASE-T cable (straight) with the E500. More Details >>
- No:22085
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The phase detection terminal has been provided with units produced since December 1999. You can identify these units with the serial number "N9Z○○○○○○" or la... More Details >>
- No:22090
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options