FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
□□□□□□ Year Month (Control number) The last digit of the production year is indicated as the Year, and the Month is indicated by 1 to 9, X (October), Y (Nove... More Details >>
- No:20982
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
The UL94V-0 flammability standard is satisfied. More Details >>
- No:20990
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
It controls the charging current immediately after the power is ON. (as a resistor for charging current limit circuit) More Details >>
- No:21150
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
A current fluctuation may result in abnormal noise from the peripheral device or the flickering fluorescent light. More Details >>
- No:21155
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
At power-ON, the signal turns ON for a moment to perform a converter initial reset. More Details >>
- No:21156
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Setting when using the FR-A7AZ and SF-V5RU
Setting of Pr.408 (Thermistor selection) is required. Set as follows. For the model of SF-V5RU ending with "T" (SF-V5RU○○T): Pr.408 = 0 For the model of SF-V... More Details >>
- No:21169
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
FR Configurator SW3 (CC-Link Seamless)
It cannot be opened because FR Configurator SW3 and FR Configurator SW3 (CC-Link Seamless) are not compatible. More Details >>
- No:21172
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
It can be performed by setting Pr.292 (Automatic acceleration/deceleration) to "8" and Pr.279 (Brake opening current) to 0%. More Details >>
- No:21186
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
FR Configurator (English version)
The English version cannot be updated from the Website. FR-SW3-SETUP-WE needs to be purchased. More Details >>
- No:21195
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
No. During JOG operation, deceleration stop is performed even though Pr.250 is set. More Details >>
- No:21199
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
421-430 of Total 1306