Built-in regenerative resistor
For both the 200 V and 400 V classes have the built-in regenerative resistor for 0.4 K to 7.5 K.The permissible power is as follows:Capacity: Short-time perm... More Details >>
- No:22021
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Use the FR-HC to suppress harmonics. It also supports power supply regenerative driving.The FR-CV and FR-RC are both power supply regeneration units.The diff... More Details >>
- No:22038
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Setting values of the FR-F800 when replaced with the FR-F400
The performance and noise countermeasure were improved and the initial value is set to "8". Try with the initial value "2" first. If the noise is distracting... More Details >>
- No:20808
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
S-shape acceleration/deceleration of the FR-D700
It does not change even when General-purpose magnetic flux vector control is performed. Pr.3 is the inflection point of the S-shape. More Details >>
- No:20834
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-D700
-
Replacement with the FR-B, B3 (A800 specification)
In the A800 base of the FR-B and FR-B3, the Easy setup wizard is not available. Thus, some functions are restricted. More Details >>
- No:20862
- Release Date:2018/08/22 16:24
- Category: FREQROL-B
-
The direct connection with the inverter like the standard model, and the connection via the GOT and relay station (programmable controller) are available. On... More Details >>
- No:20879
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The RJ-45 compatible connector (LAN cable), switching hub, and others are required The auto detection of the connection devices, externally monitoring the in... More Details >>
- No:20882
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Carrier frequency automatic reducing function
The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>
- No:20903
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Monitoring function of the FR-A800-R2R
No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>
- No:20915
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800