FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
The maximum values are kept. The values are not cleared to zero. More Details >>
- No:21015
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
Second deceleration time setting
Your suggestion is fine, but note that deceleration stop is naturally not available in case of an inverter error.In addition, considering regenerative power,... More Details >>
- No:21939
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
You cannot monitor the running frequency and conveyor speed (machine speed) simultaneously.The inverter does not have a function to output them simultaneously. More Details >>
- No:21827
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
The operation command source is automatically transferred to the connected FR-PU07 or FR-PA07. More Details >>
- No:21700
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
Set Pr.270 (Stop-on-contact control) to "1".Set Pr.184 (RES terminal function selection) to "3" to choose the RT signal function.When the terminals RL and RT... More Details >>
- No:21691
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options , FREQROL-E700
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Plug-in Options
-
Replacement of the SF-JR with the SF-PR
Since the SF-PR is more efficient compared to the SF-JR, the resistance will decrease and the load current will increase. Check the following two points when... More Details >>
- No:20949
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
-
Output phase loss protection error
- How to find out lost phaseMeasure the three-phase current when the error has occurred.The phase with a small (or no) phase current is lost.- Possibility of... More Details >>
- No:21969
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Using a higher grade power factor improving reactor
Using a reactor under a load lighter than the rated capacity slightly spoils its effect in improving the power factor.Therefore, you should use a reactor wit... More Details >>
- No:21935
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
481-490 of Total 1292