Can I use a motor of which capacity is larger than the inverter capacity?
Even when the actual load (torque) is half of the motor capacity, the current output from the inverter to the motor is not reduced to the half. Therefore, it... More Details >>
- No:21442
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Using a general-purpose inverter to drive a three-phase induction motor can save energy under the following two types of loads (application): 1. Constant-t... More Details >>
- No:21537
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Installation of external thermal
Since the inverter has a built-in motor overheat protective function called "electronic thermal O/L relay", the external thermal is not required. (If you use... More Details >>
- No:21545
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Yes. More Details >>
- No:21704
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , Others
-
Inverter selection when driving multiple motors
When driving multiple motors with a single inverter, determine the inverter capacity in one of the following two methods:1. When driving multiple motors conn... More Details >>
- No:22007
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The inverter's output voltage is controlled by switching DC voltage and has a pulse voltage waveform.(It is not a clean sine wave.)Therefore, it cannot be me... More Details >>
- No:22029
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Thermal characteristics of motor
Basically, when the motor temperature goes higher, the motor rotation speed goes lower.The motor rotation speed also changes when the inverter input power su... More Details >>
- No:22076
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Yes, they are. More Details >>
- No:20877
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
The count is resumed from 0. Thus, the times of the overflow is reset. More Details >>
- No:20902
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
JIS standard for the inverter is not established. It is required to check whether the whole machine including the inverter is compliant with JIS standard. More Details >>
- No:21023
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL