Setting the tuning data without tuning makes no difference. The tuning method of the FR-A700 is different from that of V500. Tuning can be performed by setti... More Details >>
- No:21139
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Others , FREQROL-A700
-
Gain adjustment under the speed control
Since the lower limit has been internally set, 3% or less is recognized as 3%. More Details >>
- No:21016
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
Load characteristics fault detection
Only the V/F control is related with Pr.56. The motor torque is calculated from the current value (not Pr.56) and motor constant. For the V/F control, it is ... More Details >>
- No:20893
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-F800
-
When offline auto tuning ends normally, the setting of this parameter changes to "3".This means that auto tuning completed normally.If the setting value is "... More Details >>
- No:21748
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Set Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, Pr.84, and Pr.96. More Details >>
- No:21721
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Set Pr.40 (RUN key rotation direction selection) to "1" (Reverse). More Details >>
- No:21693
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
In addition to the FR-A200E series, you can use it with the following inverters: - FR-A024- FR-A200- FR-A100E- FR-A100- FR-V200- OthersAlso, supported by the... More Details >>
- No:21588
- Release Date:2018/08/22 16:28
- Category: Engineering Software
-
Communication operation with FR-E500
We have no sample program for RS485 communication. Since the communication method of the FR-SW0-SETUP uses a different protocol from 485 communication and st... More Details >>
- No:21451
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
DC application method (Pr.162 = 0 or 10): 4 Hz or lower is regarded as 0 Hz. AC application method (Pr.162 = 3 or 13): It is not defined since it depends on ... More Details >>
- No:20905
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20840