It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>
- No:20889
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>
- No:20952
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes, the 7.5 kW or lower motor can be used for belt drive hanging and direct connection. Note that the standard models of 11 kW or higher motor are dedicated... More Details >>
- No:20962
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
-
When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>
- No:20981
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
The number of terminals: There are the same input terminals as F700P and the following terminals (4 points) are added. Safety: SI1, SI2, SIC 24 V power suppl... More Details >>
- No:21070
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
The operation panel is also compatible with the IP55 More Details >>
- No:21091
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>
- No:21121
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
-
It prevents high-frequency current due to switching that is output by the FR-HC2 from being flown into the power supply system as a filter. More Details >>
- No:21151
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The reactor generates a sound during power regeneration, but it is not abnormal. [Reason] The noise from the reactor is caused mainly by the magnetic attract... More Details >>
- No:21157
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Reverse operation is enabled by changing the setting of Pr.40. More Details >>
- No:21287
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ