Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Yes, because the same enclosure cut dimensions is adopted. More Details >>
- No:20866
- Release Date:2018/08/22 16:24
- Category: Options
-
Because the inverter status reading is stopped by the processing such as PLC in the inverter when the main circuit turns ON. It is stopped for approximately ... More Details >>
- No:20873
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Ver1.1 (Ver2.0 (full speed) compatible). USB1.1 supports Full Speed (12 Mbps) and Low Speed (1.5 Mbps) transmission speed modes. USB2.0 supports High Speed (... More Details >>
- No:21096
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
By performing offline auto tuning, other manufacturers' IPM, SPM motors can be used under PM sensorless vector control. * When an other manufacturers' magnet... More Details >>
- No:21106
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
- The 280K or lower has the installation size compatibility. - The 315K or higher does not have the installation compatibility; because the inverter unit and... More Details >>
- No:21109
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-A700
-
Yes. However, it is difficult to wind the twisted wires because they are thick. More Details >>
- No:21128
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The corresponding bit (RYB) can be used when a function other than reset is assigned to the RES terminal, but it cannot be used as the reset function. Use RY... More Details >>
- No:21142
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
-
Check that not only the current but also the various elements of the fuse such as cut-off speed and life are equivalent to those of the recommended product. More Details >>
- No:21153
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The initial value of Pr.78 (Reverse rotation prevention selection) of the MD-CX522 is "1" (reverse rotation is disabled). When performing forward rotation an... More Details >>
- No:21168
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL