- No:21127
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Others
-
It is not available and "Err" is displayed. When the FR-HC2 dedicated DU (FR-DU07-CNV) is installed to the inverter, "Err" is displayed as well. The FR-PU07 ... More Details >>
- No:21148
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
It prevents high-frequency current due to switching that is output by the FR-HC2 from being flown into the power supply system as a filter. More Details >>
- No:21151
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Check that not only the current but also the various elements of the fuse such as cut-off speed and life are equivalent to those of the recommended product. More Details >>
- No:21153
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The acceleration time is 60 Hz and 5 seconds, and deceleration time is 60 Hz and 60 seconds. More Details >>
- No:21166
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Setting when using the FR-A7AZ and SF-V5RU
Setting of Pr.408 (Thermistor selection) is required. Set as follows. For the model of SF-V5RU ending with "T" (SF-V5RU○○T): Pr.408 = 0 For the model of SF-V... More Details >>
- No:21169
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is available. Insulate the raised wiring of T-phase. More Details >>
- No:21177
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
FR Configurator (English version)
The English version cannot be updated from the Website. FR-SW3-SETUP-WE needs to be purchased. More Details >>
- No:21195
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Data with different capacity can be imported. Data with different voltage or model cannot be imported. More Details >>
- No:21196
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Watt-hour meter clear and operation hour meter clear
The values are set to Pr.170 and 171 when the monitor value of cumulative power and actual operation time overflows. It does not affect the operation. Use it... More Details >>
- No:21197
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL