FR Configurator SW3 (CC-Link Seamless)
It cannot be opened because FR Configurator SW3 and FR Configurator SW3 (CC-Link Seamless) are not compatible. More Details >>
- No:21172
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Check that not only the current but also the various elements of the fuse such as cut-off speed and life are equivalent to those of the recommended product. More Details >>
- No:21153
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:21063
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options , Others , FREQROL-B
-
The initial value of Pr.872 is set to "1" (Valid) because the A701 have regeneration unit built-in and an overvoltage may occur when the regenerative operati... More Details >>
- No:20945
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A700
-
For the products written in the FR-HEL Instruction Manual, the installation of a reactor is required and inverter + reactor is certified as UL standards. For... More Details >>
- No:20944
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Both parameter files (pr4) and system files (frc2) can be read. More Details >>
- No:20909
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
FR-A800 "Parameter for the communication setting"
These parameters are used for the communication compatible with the communication protocol of the Ethernet IP of the HMS optional circuit board (A8NEIP_2P). More Details >>
- No:20824
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Set the parameters below. For other parameters, keep the initial settings.1. Set Pr.122 (Communication check time interval) to other than "0". ("9999" is OK.... More Details >>
- No:21986
- Release Date:2018/08/22 16:30
- Category: Engineering Software
-
I want to synchronize the Z200 and E500.
If you are using analog voltage commands, connect the voltage inputs to the FR-E500 and FR-Z200 in parallel to equalize inputs to both units and speeds are s... More Details >>
- No:21929
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500 , FREQROL-Z200
-
1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>
- No:21662
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200