FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
No, it isn't. Use the multiple rating (LD, SLD) of the FR-A800. More Details >>
- No:20972
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
By setting the operating condition, such as load level and surrounding air temperature, according to the application, the inverter capacity may be lowered co... More Details >>
- No:21101
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
Notes on using single-phase 200 V
With the single-phase 200 V input specifications, the input cable current increases. Therefore, choose larger power supply capacity and NF/MC than three-phas... More Details >>
- No:21406
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Indication of potentiometer on operation panel
The potentiometer on the operation panel is initially calibrated so that the maximum indication is slightly over 60 Hz with the potentiometer turned to the m... More Details >>
- No:21427
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
12-bit digital input and others
You can switch between PU operation and external operation using the plug-in option "12-bit digital input" card and external contact signals. After setting P... More Details >>
- No:21432
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>
- No:21454
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
Difference between use with A100 and other types
Similarly to the FR-A200 and A500, four or more filters should be used also for the FR-A100. In short, it is OK if the wire penetrates the filter four times... More Details >>
- No:21468
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Number of years of service life designated by law
The number of years of service life of the inverter is not designated by law. More Details >>
- No:21497
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
When the Mitsubishi standard cage-induction motor (SF-JR 4P) and inverter of the same capacity are combined, the maximum short-time torque under magnetic flu... More Details >>
- No:21633
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>
- No:21662
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
611-620 of Total 1292