FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
You can select from the output power (in 0.01 kW units) and cumulative energy (in 1 kWh/0.01 kWh units). More Details >>
- No:21885
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Yes. Set the first monitor code in the lower 8 bits and the second monitor code in the upper 8 bits of RWwn.Set H6F to the first monitor code, and H70 to the... More Details >>
- No:21824
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
No. You cannot check the accumulated number of rotations on the monitor. More Details >>
- No:21715
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Its protective structure conforms to IP20.Therefore it is not waterproof. More Details >>
- No:21701
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
Can I use digital operation panel FR-DU01?
You cannot use it with the standard and multi-function products. It can be connected to the dedicated PU operation type only. (Note that the FR-DU01 is an op... More Details >>
- No:21595
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-U100
-
Fault output signal when inverter trips
Only the unit type SC-A□□U has fault output signals. (Terminals Y1 and SD open collector output permissible load 24 VDC 0.1 A)The box type SC-A□□B indicates ... More Details >>
- No:21580
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
-
Unit type: SC-A□□U can be installed on the DIN rail. Box type: SC-A□□B cannot be installed on the DIN rail. More Details >>
- No:21579
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
-
To almost "1". (With load factor of 100%) More Details >>
- No:21577
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
A reference sine wave signal is generated inside the high power factor converter, and transistors are configured and PWM switching is performed in the conver... More Details >>
- No:21574
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
Number of inverters that can be connected to a 20 A branch circuit breaker
The basic idea is the same, but the total capacity should be 3.7 kW. (The maximum capacity is also 3.7K.) More Details >>
- No:21508
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others , FREQROL-A024
611-620 of Total 1292