FR Configurator SW3 (CC-Link Seamless)
It is supports FR Configurator Ver.4.90 or later. More Details >>
- No:21173
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
It is one of other communication errors. The communication is not established. Check the communication settings. More Details >>
- No:21176
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Communication EEPROM write selection (Pr.342)
They are cleared by the RES signal from the external terminals or inverter reset from the communication. More Details >>
- No:21221
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is available since June, 2007. The model is FR-E7TR. More Details >>
- No:21300
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
It is available since November, 2007. The model is FR-A7ND E kit. More Details >>
- No:21321
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
-
Countermeasure against the instantaneous power failure with the inverter
The power cannot be supplied to the control power supply separately for the FR-A024/A044 and small type FR-E500. Therefore, the UPS is not available. More Details >>
- No:21368
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024 , FREQROL-E500
-
Vector control of the inverter
The speed fluctuation ratio under Advanced magnetic flux vector control of the FR-A500 is as follows. Without encoder: ±1% With encoder (with A5AP): ±0. 02 %... More Details >>
- No:21369
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The output current monitor of the inverter displays the output current effective value of the three phases measured by the current sensor. It does not displa... More Details >>
- No:21373
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Countermeasures when input power supply is turned off upon equipment fault
1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>
- No:21390
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL