FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
Real sensorless vector control
For tuning of a single motor with no load, set Pr.96 to "101". When a load is connected, set Pr.96 to "1" (without motor rotation). Since Real sensorless vec... More Details >>
- No:21325
- Release Date:2018/08/22 16:27
- Category: FREQROL-A700
-
This is because the version of the FR-SW3 is old, and the version of INV is new (Pr.551 = 9999 is added for the products manufactured in December 2011 or lat... More Details >>
- No:21134
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Number of terminals: Same input terminals as the A700 series, and the following two terminals are added. Safety: SI1, SI2, SIC 24 V power supply: +24 * The t... More Details >>
- No:21099
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
Output current: Because the filter, effective value of the output current displayed on the operation panel, is included, the momentary fluctuation is difficu... More Details >>
- No:20919
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
No, it cannot. Use the FR-HC2 dedicated reactor and outside box. More Details >>
- No:20807
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
1. You can implement stop-on-contact.2. When implementing stop-on-contact, use the inverter to decelerate the motors to reduce the impact upon stop-on-contac... More Details >>
- No:22041
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Take the following countermeasure:1. If the thermal trips in low-speed operation, trips can be avoided, depending on the external thermal relay operation cha... More Details >>
- No:21954
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>
- No:21937
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
Advanced magnetic flux vector control
Yes. Set Pr.89 (Speed control gain) to "0". More Details >>
- No:21690
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Countermeasure against inverter noise
You can attach the following filters to the inverter input side:- Line noise filter (FR-BLF, FR-BSF01)- Radio noise filter (FR-BIF) While it is a good idea ... More Details >>
- No:21528
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
631-640 of Total 1292