Common terminals of control circuit
If you ground the common terminals of the control circuit, it is connected with the inverter's earthing and the inverter's noise may be input to the control ... More Details >>
- No:22037
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Current value monitor indicator
The measurable frequency range and measurement precision of the inverter's output current greatly differ depending on the measurement instrument.Check with t... More Details >>
- No:22079
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Pulse frequency characteristics of terminal FM
The terminal FM output pulse is directly proportional to the inverter output frequency.With the initial setting, 1440 pulses/sec are output at 60 Hz (Pr.55),... More Details >>
- No:22080
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Winding diameter calculation is available for all controls (dancer feedback speed control, tension sensor feedback speed control, tension sensorless torque c... More Details >>
- No:20886
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes, the options are the same as the FR-A800 standard model. Note that two options can be added at maximum. (One option is already used as standard.) Other c... More Details >>
- No:20922
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It depends on machine specifications. It depends on the accuracy of the line speed input and parameter setting of material thickness. More Details >>
- No:20927
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The CC-Link communication can be supported by using option FR-A7NC E kit. More Details >>
- No:21031
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It depends on the scan time. More Details >>
- No:21042
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Overshooting of the speed due to the acceleration/deceleration may be the cause. Overshooting is more likely to occur when the load inertia is too high. As a... More Details >>
- No:21216
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Comparison of the speed change rate
Speed fluctuation ratio differs depending on the control method as follows. - V/F control?????????2 to 5% (At the encoder feedback: 0.02%)- General-purpose m... More Details >>
- No:21377
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
61-70 of Total 1292