FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
Automatic restart after instantaneous power failure
The inverter restart operation is disabled at turn-OFF of the CS signal while a value other than "9999" (with restart) is set in Pr.57. The terminals CS and ... More Details >>
- No:21255
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
FR-FS-0.4K: 35 W, FR-FS-0.8K: 65 W, Noise filter: 4 W More Details >>
- No:21165
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
A separate power supply is required according to the encoder power supply specification. More Details >>
- No:21090
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
The output of the FM terminal becomes the current output of the CA. More Details >>
- No:21060
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Options
-
The inrush current limit circuit is not built in the FR-A842 (inverter unit). It is built in the FR-CC2 (converter unit), which is combined with the FR-A842.... More Details >>
- No:21059
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Options
-
The time from when the frequency command is applied until it is reflected on the operation of the motor is different. For the analog input, the multiple anal... More Details >>
- No:21050
- Release Date:2018/08/22 16:25
- Category: FREQROL-D700
-
Both settings of Pr.83 and Pr.84 are enabled immediately. However, the output voltage is not changed because the value of Pr.83 has little influence on Vecto... More Details >>
- No:21022
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
V/F control/Advanced magnetic flux vector control/Sensorless vector control: 0.3 rpm increments, Vector control with encoder: 0.1 rpm increments More Details >>
- No:20960
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
It is because the CC-Link monitor is designed to hold the value at an error occurrence. More Details >>
- No:20946
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
Yes, the current is limited under the PM sensorless control. More Details >>
- No:20936
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
691-700 of Total 1306