Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>
- No:21976
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500 , FREQROL-F500
-
The brake resistor is not built in the inverter. Purchase the optional resistor and connect it to the inverter.Inverter only (without resistor)Continuous reg... More Details >>
- No:21989
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Set 3 kg (intermediate value) for the load weight 1 to 5 kg. More Details >>
- No:20953
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
The time from when the frequency command is applied until it is reflected on the operation of the motor is different. For the analog input, the multiple anal... More Details >>
- No:21050
- Release Date:2018/08/22 16:25
- Category: FREQROL-D700
-
SD1148 can turn ON multiple bits such as STF and RH simultaneously. SM turns ON bits individually. When SD1148 is H5, it is same as when SM1200 (STF) and SM1... More Details >>
- No:21057
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
No. Check the parameter setting of the A500(L), and then adjust the parameter setting of the A800 to those of the A500(L). For the details, refer to the repl... More Details >>
- No:21108
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-A500
-
The operation cannot be manually switched to the commercial power supply operation at an inverter fault. The operation can be automatically switched to the c... More Details >>
- No:21191
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Refer to the inverter capacity. More Details >>
- No:21200
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Set Pr.55 (Frequency monitoring reference) of the first inverter to 70 Hz. More Details >>
- No:21257
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>
- No:21378
- Release Date:2018/08/22 16:27