Waiting time at the instantaneous power failure
The count is started from the power failure. The count is started after the power restoration or reset release when the power failure period is too long, or ... More Details >>
- No:20939
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The English version of SW3 can be installed with the product ID of FR Configurator2 if it is Ver.5.50 or later. Since Ver.5.50 or former does not have a prod... More Details >>
- No:20913
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>
- No:20888
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
The CAD data is found on the member's page of Mitsubishi Electric FA Global Website. More Details >>
- No:22091
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Others
-
Current value monitor indicator
The measurable frequency range and measurement precision of the inverter's output current greatly differ depending on the measurement instrument.Check with t... More Details >>
- No:22079
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Can I set the FR-F series parameters?
The FREQROL-F500 series has been already supported by the setup software released since February 2000. More Details >>
- No:22068
- Release Date:2018/08/22 16:30
- Category: Engineering Software
-
Current increase at motor stop
If the current increases when the motor stops under V/F control (at low speed under a light load), the motor is considered to be in the overexcitation state.... More Details >>
- No:21997
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Built-in potentiometer and current input switching control
For setting the frequency, you cannot switch between the operation panel potentiometer and current input from an external source.To switch between the extern... More Details >>
- No:21985
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Since the Advanced magnetic flux vector control method uses slip compensation to compensate the frequency, the value is not shown as exactly 60 Hz.For V/F co... More Details >>