Angular velocity change control
The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>
- No:22086
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-V200
-
1. The braking torque can be considered 50% of the motor rated torque.2. The largest stress the DC injection brake gives to the motor is the motor heat gener... More Details >>
- No:22088
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Check if the communication setting parameters (Pr.117 to Pr.124) are set to the same values between the inverter and personal computer.Note that communicatio... More Details >>
- No:22105
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-A500
-
FR-A800 "Parameter for the communication setting"
These parameters are used for the communication compatible with the communication protocol of the Ethernet IP of the HMS optional circuit board (A8NEIP_2P). More Details >>
- No:20824
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
S-shape acceleration/deceleration of the FR-D700
It does not change even when General-purpose magnetic flux vector control is performed. Pr.3 is the inflection point of the S-shape. More Details >>
- No:20834
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-D700
-
It is 2 to 3 ms. By setting Pr.289 Inverter output terminal filter and Pr.699 Input terminal filter, the FR-A700 can be compatible with the response of the t... More Details >>
- No:20899
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Carrier frequency automatic reducing function
The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>
- No:20903
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Yes, the current is limited under the PM sensorless control. More Details >>
- No:20936
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
Communication specifications for connection of multiple inverters
Use the RS485 terminal for the multiple communication of the A series/F series inverters.* Communication with the PU connector is only one-to-one connection. More Details >>
- No:20998
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Gain adjustment under the speed control
Since the lower limit has been internally set, 3% or less is recognized as 3%. More Details >>