FAQ within [ Inverters-FREQROL ]
-
Operation of the motor with a brake
For the general-purpose inverter, the motor stop cannot be detected accurately because the actual motor speed from a motor is not input. In general, the RUN ... More Details >>
- No:21375
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Inverter UL and CSA standard product document
The certificate of the standard product is managed by the branch office. Please ask the nearest branch office. More Details >>
- No:21381
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
From Z100 to A520: Use the FR-AAT01 to replace the Z100 with the A520. From Z100 to E520: No attachment is available since E520 is a new series. From Z100 to... More Details >>
- No:21447
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options , FREQROL-Z100
-
Countermeasure against harmonics
Perform calculation given in the harmonic suppression guidelines, and if the limit value is exceeded, you may also need to insert the ACL. Note that you cann... More Details >>
- No:21465
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
In addition to the dedicated motor (SF-VR series), the SF-JR series motor with an encoder can be used. You can also use a standard motor by combining it with... More Details >>
- No:21653
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
Calculation of acceleration/deceleration time
As the inverter, you can basically use the equation below to calculate the acceleration/deceleration time.Note that you should consider a factor of 120% for ... More Details >>
- No:21965
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Switching between forward and reverse rotations
When you switch the inverter to the reverse rotation while it is rotating in the forward direction, it decelerates to stop over the deceleration time (set wi... More Details >>
- No:22077
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Frequency search of the FR-A800/FR-F800
DC voltage is applied when Pr.162 = 0, and AC voltage is applied when Pr.162 = 3 or 13. For the AC, the operation is easier to continue than the DC and the i... More Details >>
- No:20831
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Residual voltage at the output shutoff
The rotation speed has almost no effect. The residual voltage increases when the torque boost is increased, but no adjustment is required. More Details >>
- No:20906
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Yes. More Details >>
- No:20910
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software