FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>
- No:21161
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
It bypasses (removes) high-frequency current due to switching that is output by the FR-HC2 to prevent it from being flown into the power supply system as a f... More Details >>
- No:21152
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>
- No:21121
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
-
Yes, the resistance values are the same. More Details >>
- No:21020
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
Output current: Because the filter, effective value of the output current displayed on the operation panel, is included, the momentary fluctuation is difficu... More Details >>
- No:20919
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Monitoring function of the FR-A800-R2R
No, they cannot be monitored when Pr.363 is other than "5". They are enabled only when Pr.363 = 5. More Details >>
- No:20915
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Selection method of the FR-ABR
The multiple rating is adopted from the FR-A800 series and the motor and the inverter are no longer one-to-one. Thus, considering the combination that the mo... More Details >>
- No:20846
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>
- No:20845
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
- No:20821
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Motor rated rotations per minute
The inverter is capable of output up to the maximum frequency. It is the matter of whether the motor used support high-speed operation. In the situation you ... More Details >>
- No:22099
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
761-770 of Total 1292