Can I use a motor of which capacity is larger than the inverter capacity?
Even when the actual load (torque) is half of the motor capacity, the current output from the inverter to the motor is not reduced to the half. Therefore, it... More Details >>
- No:21442
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Using a general-purpose inverter to drive a three-phase induction motor can save energy under the following two types of loads (application): 1. Constant-t... More Details >>
- No:21537
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Since the converter in the high power factor converter section performs PWM switching, the leakage current increases to the same level as the general-purpose... More Details >>
- No:21558
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
Can I use it with the single-phase power supply?
You can use the inverter with the single-phase 200 V power supply. However, since ripple current flowing through the capacitor increases and the converter an... More Details >>
- No:21611
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Using existing potentiometer by replacing inverter
It is OK if the resistance value of the speed varying potentiometer's resistance is 2 kΩ.Use the speed varying potentiometers used with the existing inverter... More Details >>
- No:21962
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Installing parameter unit outside control panel
You can install the operation panel FR-DU04 (or parameter unit FR-PU04) on the enclosure surface by connecting it with the inverter via a cable.To do this, d... More Details >>
- No:22044
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Yes, they are. More Details >>
- No:20900
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Inverters with the components fixed on the circuit board with an adhesive, an countermeasure against the connector failing, or the cables tied (fixed) togeth... More Details >>
- No:20931
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is preferred. The accuracy becomes worse when the gap between the setting value and actual value increases. More Details >>
- No:20932
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
S45C (Carbon steel) is used. More Details >>
- No:21025