FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
The parameter file (extension: pr3) can be imported. The system file (extension: mel) cannot be imported. More Details >>
- No:21194
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Watt-hour meter clear and operation hour meter clear
The values are set to Pr.170 and 171 when the monitor value of cumulative power and actual operation time overflows. It does not affect the operation. Use it... More Details >>
- No:21197
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no setting to disable it, but setting a high torque limit level such as 400 % can disable the limit. More Details >>
- No:21217
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Inverter installation when using the FR-A7NCE
Normally, the required space for A700 3.7K or lower is 1 cm. However, when using CC-Link IE, it needs to be separated for 5 cm or more to pass the cable. More Details >>
- No:21227
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The FR-E540 uses common input for the control power supply and main circuit power supply. (It has only one power supply input terminal.) Therefore, you canno... More Details >>
- No:21395
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Harmonic suppression guidelines
A 200 V class inverter of 3.7 kW or smaller is the target of the harmonic suppression guidelines for household appliances and general-purpose products, and i... More Details >>
- No:21553
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
You can do it by using the optional DIN rail attachment (FR-DU01/02). More Details >>
- No:21598
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-U100
-
Compatibility of the function with FR-A200
Yes. Compared with the FR-A200:- The auto tuning function is added.- Response current limit operation is improved.- The carrier frequency range is extended. ... More Details >>
- No:21629
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
When controlling motor with brake by inverter
Use the RUN signal to turn ON and OFF the brake.Using the MRS (output shutoff) signal to turn ON the brake shuts off the inverter's output and reduces influe... More Details >>
- No:21960
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Imbalanced input side power supply
1. Power supply voltage phase imbalance toleranceMitsubishi inverter's input power supply voltage phase imbalance tolerance is ±3%.If the phase imbalance exc... More Details >>
- No:21987
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
71-80 of Total 1292