Speed precision of Advanced magnetic flux vector control
The speed precision for each model is as follows:FR-K440 with PG: 1% or less of the maximum speed (3500 rpm)FR-A540 without PG (Advanced flux vector): 1% or ... More Details >>
- No:22013
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Frequency misalignment at current input
It seems that calibration of the current input is slightly incorrect.By using Pr.904 (Frequency setting current bias) and Pr.905 (Gain), you can calibrate th... More Details >>
- No:22014
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Control wire of FR-HC RDY signal
The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>
- No:22017
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
1. Changing frequency to 0 Hz(1) Set Pr.8 (Deceleration time) to 0 second.If the load is large, the stall prevention function may work to lengthen decelerati... More Details >>
- No:22019
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Many geared motors cannot continuously operate at low speed (for example, slower than 6 Hz) due to grease viscosity.If the motor you are using is of this typ... More Details >>
- No:22028
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A024
-
Be sure to use the FR-E5P to mount the operation panel.This is because the board is bare on the back of the operation panel and a dedicated connector is requ... More Details >>
- No:22030
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Common terminals of control circuit
If you ground the common terminals of the control circuit, it is connected with the inverter's earthing and the inverter's noise may be input to the control ... More Details >>
- No:22037
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Notes when inverter capacity is larger than motor capacity
When using one-rank-higher inverter, as you mention, you need to care about the setting of the electronic thermal O/L relay.Setting the electronic thermal O/... More Details >>
- No:22040
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Installing parameter unit outside control panel
You can install the operation panel FR-DU04 (or parameter unit FR-PU04) on the enclosure surface by connecting it with the inverter via a cable.To do this, d... More Details >>
- No:22044
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Connecting the brake resistor allows for quick deceleration because the regenerative power is processed. (The brake torque increases.)Therefore, when an exte... More Details >>
- No:22045
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500