FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
-
A separate power supply is required according to the encoder power supply specification. More Details >>
- No:21090
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
For the FR-F800 series, in addition to the conventional Optimum excitation control, Advanced optimum excitation control with the improved starting torque is ... More Details >>
- No:21072
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
It is a gap intentionally set in the movement direction between the machine elements that mesh with each other such as a cogwheel used for the reduction gear. More Details >>
- No:21065
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
-
SD1148 can turn ON multiple bits such as STF and RH simultaneously. SM turns ON bits individually. When SD1148 is H5, it is same as when SM1200 (STF) and SM1... More Details >>
- No:21057
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
FR Configurator SW3 is not included in IQWorks. Therefore, FR Configurator SW3 cannot be installed with the product ID of IQWorks. However, SW1DND-FRC2 (FR C... More Details >>
- No:21033
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Combination of the FR-A800 and MM-BF
Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>
- No:21000
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
□□□□□□ Year Month (Control number) The last digit of the manufactured year is indicated as the Year, and the Month is indicated by 2 to 9, X (October), Y (No... More Details >>
- No:20984
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
No, it isn't. Use the multiple rating (LD, SLD) of the FR-A800. More Details >>
- No:20972
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
The internal transistor of the HC2 stops by turning on the SOF signal and stopping the converter. As a result, regenerative driving is not performed. However... More Details >>
- No:20941
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Carrier frequency automatic reducing function
The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>
- No:20903
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
801-810 of Total 1292