Check if the communication setting parameters (Pr.117 to Pr.124) are set to the same values between the inverter and personal computer.Note that communicatio... More Details >>
- No:22105
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-A500
-
- Both 200 V and 400 V can be used only with the capacity 22 kW or higher. - The rated current (capacity) is derated. (For the detail, refer to the Instructi... More Details >>
- No:20802
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Insulation level of the MM-EFS
F class (155 deg C) More Details >>
- No:20809
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others
-
Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>
- No:20812
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Seamless communication of FR Configurator SW3
The communication via the MELSECNET is not available. More Details >>
- No:20830
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Switching time of the FR-A800 control
20 ms or less is required to switch the control with the MC signal. More Details >>
- No:20838
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
No, they do not. Pr.72 is invalid at the offline auto tuning. It is also invalid when the motor rotates with Pr.96 = 101. More Details >>
- No:20878
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The direct connection with the inverter like the standard model, and the connection via the GOT and relay station (programmable controller) are available. On... More Details >>
- No:20879
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
It is not possible because the RS-485 terminal block is not installed. Use the FR-A800 (RS-485 communication type) when performing the RS-485 communication. More Details >>
- No:20881
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The RJ-45 compatible connector (LAN cable), switching hub, and others are required The auto detection of the connection devices, externally monitoring the in... More Details >>
- No:20882
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800