UVT will occur when reactor is not connected. Always connect a reactor that matches the motor capacity. More Details >>
- No:20978
 - Release Date:2018/08/22 16:25
 - Category: Inverters-FREQROL , FREQROL-A800
 
 - 
      
      
The initial value of Pr.872 is set to "1" (Valid) because the A701 have regeneration unit built-in and an overvoltage may occur when the regenerative operati... More Details >>
- No:20945
 - Release Date:2018/08/22 16:25
 - Category: Inverters-FREQROL , FREQROL-A700
 
 - 
      
      
Output current: Because the filter, effective value of the output current displayed on the operation panel, is included, the momentary fluctuation is difficu... More Details >>
- No:20919
 - Release Date:2018/08/22 16:25
 - Category: Inverters-FREQROL , Engineering Software
 
 - 
      
      
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
 - Release Date:2018/08/22 16:24
 - Category: Inverters-FREQROL , FREQROL-A800
 
 - 
      
      
The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
- No:20865
 - Release Date:2018/08/22 16:24
 - Category: FREQROL-E700
 
 - 
      
      
Yes, they can. More Details >>
- No:20856
 - Release Date:2018/08/22 16:24
 - Category: FREQROL-A800
 
 - 
      
Leakage current of the FR-HAL/FR-HEL
It is less than 1 mA. More Details >>
- No:20844
 - Release Date:2018/08/22 16:24
 - Category: Inverters-FREQROL , Options
 
 - 
      
      
- Both 200 V and 400 V can be used only with the capacity 22 kW or higher. - The rated current (capacity) is derated. (For the detail, refer to the Instructi... More Details >>
- No:20802
 - Release Date:2018/08/22 16:24
 - Category: Inverters-FREQROL , Options
 
 - 
      
      
1. As the reactor (FR-HCL) is connected when connecting the FR-HC, do not connect the FR-BAL. 2. The noise filter can be connected to the input side of the F... More Details >>