FAQ


FAQAbout Products
 - FAQ > Drive Products > Inverters-FREQROL
 
FAQ
Keyword Search
Inverters-FREQROL
FAQ within [ Inverters-FREQROL ]
- 
      
      
With the FREQROL-U100 series, pressing and holding the [SET] switches to the current monitor. More Details >>
- No:22073
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , FREQROL-U100
 
 - 
      
Switching from star-delta operation
It is probable that the torque is insufficient because the load characteristics and inverter output characteristics do not match and the output current value... More Details >>
- No:22049
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL
 
 - 
      
      
Use the FR-HC to suppress harmonics. It also supports power supply regenerative driving.The FR-CV and FR-RC are both power supply regeneration units.The diff... More Details >>
- No:22038
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , Options
 
 - 
      
Using shielded wires for frequency meter connection
Connect the shield to the terminal SD. More Details >>
- No:22034
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , FREQROL-A500
 
 - 
      
Driving two motors with different capacities
It is OK to drive motors by switching the electromagnetic contactor on the inverter's output side.It is also OK if the motor capacity is small. However, if t... More Details >>
- No:22022
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , FREQROL-A500
 
 - 
      
Installation method of AM-5 terminal ammeter
The AM-5 output is 0 to 10 VDC voltage output.Therefore, you need to install a voltmeter.Also, since the inverter output current is displayed, the scale of t... More Details >>
- No:22016
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , FREQROL-F500
 
 - 
      
EMC compliant filter terminal cover
The SF1258 has the terminal cover.Although the SF1259 to SF1263 do not have the terminal covers and their terminals are bare, rubber tubes to cover them are ... More Details >>
- No:21956
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , Options
 
 - 
      
Selection of high-duty brake resistor
Select the high-duty brake resistor according to the inverter capacity. More Details >>
- No:21953
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
 
 - 
      
Electronic thermal O/L relay setting
Set Pr.9 to the rated current at 50 Hz or a value 1.1 times as the rated current at 60 Hz.You can specify the motor type with Pr.71 (Applied motor). For a co... More Details >>
- No:21941
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL
 
 - 
      
Second deceleration time setting
Your suggestion is fine, but note that deceleration stop is naturally not available in case of an inverter error.In addition, considering regenerative power,... More Details >>
- No:21939
 - Release Date:2018/08/22 16:30
 - Category: Inverters-FREQROL
 
 
911-920 of Total 1306