12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>
- No:21657
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
It can be output by attaching the plug-in option FR-VPA, FR-VPB, or FR-VPC. Note that the output format depends on the option type. FR-VPA: Open collector ou... More Details >>
- No:21643
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
What functions are added by upgrading?
The following functions are added by upgrading: - Slip compensation function- Serial communication function- Frequency jump- 15-speed operation- Zero current... More Details >>
- No:21619
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
No load current value of motor
No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>
- No:21534
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
Number of years of service life designated by law
The number of years of service life of the inverter is not designated by law. More Details >>
- No:21497
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>
- No:21485
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
Difference between use with A100 and other types
Similarly to the FR-A200 and A500, four or more filters should be used also for the FR-A100. In short, it is OK if the wire penetrates the filter four times... More Details >>
- No:21468
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
I want to shorten deceleration time of small capacity motor
You can use an inverter with a larger capacity than the motor. You cannot connect a brake resistor to the FR-E520-0.1K and 0.2K. With the FR-E520-0.1K or 0.2... More Details >>
- No:21463
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Since the stall prevention function works during acceleration and the inverter does not reach the commanded speed, set Pr.156 (Stall prevention operation sel... More Details >>
- No:21460
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
There is a 10 ms delay after the inverter recognizes the start command (STF OR STR) before it starts decelerating. The delay is 10 ms. A delay of 100 ms is i... More Details >>
- No:21445
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500