Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ Options ]

1-10 of Total 127

prev 1 / 13page next
  • Radio noise filter (FR-BIF)

    A radio noise filter can be used with a built-in filter. More Details >>

    • No:21113
    • Release Date:2018/08/22 16:25
  • Sine wave filter

    The sine wave filter can be applied only under V/F control. When Pr.72 PWM frequency selection is set to 25, V/F control is set automatically. The applicable... More Details >>

    • No:21068
    • Release Date:2018/08/22 16:25
  • Installation of FR-BLF

    The following benefits are provided when the FR-BLF is installed on the input side or output side.Choose the side to install the FR-BLF considering these ben... More Details >>

    • No:22026
    • Release Date:2018/08/22 16:30
  • FR-CV

    Use the FR-HC to suppress harmonics. It also supports power supply regenerative driving.The FR-CV and FR-RC are both power supply regeneration units.The diff... More Details >>

    • No:22038
    • Release Date:2018/08/22 16:30
  • Parameter unit

    The FR-PU07(BB) can be used with some restrictions.* The major restrictions are as follows. - Pr.1000 or later cannot be set. - Alarms or warnings that are a... More Details >>

    • No:21119
    • Release Date:2018/08/22 16:26
  • Difference between FR-AU01 and AU01A

    The major changes from FR-AU01 to FR-AU01A include 1. Case material and 2. Lead wire terminal process method. The FR-AU01A has a backward compatibility with ... More Details >>

    • No:21452
    • Release Date:2018/08/22 16:27
  • FR-RC selection

    1. The 100% braking torque means the 100% motor rated torque. Do not consider the continuous regenerative driving based on the braking torque. Consider the r... More Details >>

    • No:22023
    • Release Date:2018/08/22 16:30
  • EMC compliant filter terminal cover

    The SF1258 has the terminal cover.Although the SF1259 to SF1263 do not have the terminal covers and their terminals are bare, rubber tubes to cover them are ... More Details >>

    • No:21956
    • Release Date:2018/08/22 16:30
  • What happens if the supplied reactor and outside box are not used?

    Harmonics cannot be suppressed (controlled) correctly and noise cannot be removed. Be sure to connect the supplied reactor and outside box to the inverter. More Details >>

    • No:21557
    • Release Date:2018/08/22 16:28
  • Phase detection terminal

    The phase detection terminal has been provided with units produced since December 1999. You can identify these units with the serial number "N9Z○○○○○○" or la... More Details >>

    • No:22090
    • Release Date:2018/08/22 16:30

1-10 of Total 127

Inquiries