FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > Options
FAQ
Keyword Search
FAQ within [ Options ]
-
Yes, it is. More Details >>
- No:20968
- Release Date:2018/08/22 16:25
-
For the 200 V type, the leakage current at the delta connection is 5 mA. For the 400 V type, it is 10 mA. More Details >>
- No:20835
- Release Date:2018/08/22 16:24
-
No, it cannot. Use the FR-HC2 dedicated reactor and outside box. More Details >>
- No:20807
- Release Date:2018/08/22 16:24
-
Noise filtering and harmonics suppression are different matters and you need to install the line noise filter (FR-BSF01) against noise and DCL (FR-BEL) again... More Details >>
- No:21548
- Release Date:2018/08/22 16:28
-
It is for the HIV cable. More Details >>
- No:20850
- Release Date:2018/08/22 16:24
-
A current fluctuation may result in abnormal noise from the peripheral device or the flickering fluorescent light. More Details >>
- No:21155
- Release Date:2018/08/22 16:26
-
Yes. However, it is difficult to wind the twisted wires because they are thick. More Details >>
- No:21128
- Release Date:2018/08/22 16:26
-
Regenerative driving capability
Continuous 100% regenerative braking torque is available for the rated capacity of the high power factor converter. (The same braking ability of the FR-A201 ... More Details >>
- No:21563
- Release Date:2018/08/22 16:28
-
The carrier frequency for the FR-B3 is 2 kHz. For the low noise type FR-B3-N, it is 14.5 kHz. More Details >>
- No:21181
- Release Date:2018/08/22 16:26
-
Using a higher grade power factor improving reactor
Using a reactor under a load lighter than the rated capacity slightly spoils its effect in improving the power factor.Therefore, you should use a reactor wit... More Details >>
- No:21935
- Release Date:2018/08/22 16:30
91-100 of Total 127