FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > Options
FAQ
Keyword Search
FAQ within [ Options ]
-
It controls the charging current immediately after the power is ON. (as a MC (magnetic contactor) for the charging current limit circuit, etc) More Details >>
- No:21149
- Release Date:2018/08/22 16:26
-
At power-ON, the signal turns ON for a moment to perform a converter initial reset. More Details >>
- No:21156
- Release Date:2018/08/22 16:26
-
It is not available and "Err" is displayed. When the FR-HC2 dedicated DU (FR-DU07-CNV) is installed to the inverter, "Err" is displayed as well. The FR-PU07 ... More Details >>
- No:21148
- Release Date:2018/08/22 16:26
-
For the 200 V class, the 7.5K, 15K, 30K, and 55K models are available. For the 400 V class, the 7.5K, 15K, 30K, and 55K models are available. Each requires t... More Details >>
- No:21576
- Release Date:2018/08/22 16:28
-
Combination with power factor improving reactor
It cannot be combined with the power factor improving reactor. (Since the power factor is further improved by the high power factor converter, it is not requ... More Details >>
- No:21560
- Release Date:2018/08/22 16:28
-
For the inverter with capacity of 160K or higher, the fuse is built in its DC part. More Details >>
- No:20940
- Release Date:2018/08/22 16:25
-
To almost "1". (With load factor of 100%) More Details >>
- No:21577
- Release Date:2018/08/22 16:28
-
Because RSO (converter reset) of the HC2 is connected to RES of the inverter, the inverter is reset along with the HC2 reset. (Refer to the wiring diagram in... More Details >>
- No:20948
- Release Date:2018/08/22 16:25
-
1. As the reactor (FR-HCL) is connected when connecting the FR-HC, do not connect the FR-BAL. 2. The noise filter can be connected to the input side of the F... More Details >>
- No:22101
- Release Date:2018/08/22 16:30
-
It is available. Insulate the raised wiring of T-phase. More Details >>
- No:21177
- Release Date:2018/08/22 16:26
111-120 of Total 127