  • FR-XC

    - Both 200 V and 400 V can be used only with the capacity 22 kW or higher. - The rated current (capacity) is derated. (For the detail, refer to the Instructi... More Details >>

    • No:20802
    • Release Date:2018/08/22 16:24
  • Difference between use with A100 and other types

    Similarly to the FR-A200 and A500, four or more filters should be used also for the FR-A100.  In short, it is OK if the wire penetrates the filter four times... More Details >>

    • No:21468
    • Release Date:2018/08/22 16:27
  • FR-A5CN

    When the heat sink is outside, since the heat sink and fan are not waterproof, you need to enclose them so that they are not exposed to the spray of water. More Details >>

    • No:21435
    • Release Date:2018/08/22 16:27
  • FR-HC2

    It controls the charging current immediately after the power is ON. (as a resistor for charging current limit circuit) More Details >>

    • No:21150
    • Release Date:2018/08/22 16:26
  • FR-HAL/HEL

    For 200 V: The cover is attached for 15 K or lower. No cover is attached for 18.5 K or higher. For 400 V: The cover is attached for 55 K or lower. No cover i... More Details >>

    • No:20988
    • Release Date:2018/08/22 16:25
  • Fault output terminal load pattern

    The fault output terminals A and C, and B and C of the power regeneration converter FR-RC are not capable of a micro load of 5 VDC±5%, 10 mA. The minimum loa... More Details >>

    • No:21966
    • Release Date:2018/08/22 16:30
  • FR-CVL

    Keep a clearance of "minimum 10cm each on top and bottom and minimum 5cm each on right and left". More Details >>

    • No:21178
    • Release Date:2018/08/22 16:26
  • FR-XC

    The power factor is 0.99 or more (at rated load). More Details >>

    • No:20803
    • Release Date:2018/08/22 16:24
  • Inverter selection when multiple inverters are to be connected

    Be sure to use a high power factor converter with the capacity higher than the total capacity of the inverters connected. (Note: One or more of the inverters... More Details >>

    • No:21565
    • Release Date:2018/08/22 16:28
  • FR-A7NS

    Yes, it is. More Details >>

    • No:20968
    • Release Date:2018/08/22 16:25