Control wire of FR-HC RDY signal
The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>
- No:22017
- Release Date:2018/08/22 16:30
-
Noise filtering and harmonics suppression are different matters and you need to install the line noise filter (FR-BSF01) against noise and DCL (FR-BEL) again... More Details >>
- No:21548
- Release Date:2018/08/22 16:28
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
-
It is available if the option FR-A8TAT (Control circuit terminal block intercompatibility attachment) is installed. (Some functions have restrictions. For th... More Details >>
- No:21087
- Release Date:2018/08/22 16:25
-
No. They can be connected with the connection cable (FR-CB20[]). [] indicates cable length (1 m, 3 m, 5 m). More Details >>
- No:21081
- Release Date:2018/08/22 16:25
-
Approximately 2 years when the FR-LU08 is not energized and the real-time clock function is enabled. More Details >>
- No:21084
- Release Date:2018/08/22 16:25
-
Installation necessity of a DC reactor
A DC reactor connection is required under the following conditions. - Inverter capacity is 75K or higher - Motor capacity is 75 kW or higher. If any of the a... More Details >>
- No:21077
- Release Date:2018/08/22 16:25
-
Proper use of AC reactor and DC reactor
1. ACL has the input power factor of approximately 90% and DCL has the input power factor of approximately 95%. Therefore, DCL has a higher input power facto... More Details >>
- No:21949
- Release Date:2018/08/22 16:30
-
Connecting multiple inverters to single high power factor converter
Up to 6 units. If you connect 7 or more inverters, the permissible output of control signals is exceeded. Be sure to use a high power factor converter with t... More Details >>
- No:21566
- Release Date:2018/08/22 16:28
-
The output voltage is approximately 300 VDC for the 200 V class and approximately 600 VDC for the 400 V class. The output voltage fluctuates due to fluctuat... More Details >>
- No:21561
- Release Date:2018/08/22 16:28