  • Control cable between high power factor converter and inverter

    Connect the high power factor converter and inverter directly with a control cable, without using a relay. Since a fast-response is required to shut off the ... More Details >>

    • No:21555
    • Release Date:2018/08/22 16:28
  • DC reactor

    If using an inverter with capacity of 75K or higher, or motor with capacity of 75 kW or higher, always select and install the inverter based on the capacity ... More Details >>

    • No:21112
    • Release Date:2018/08/22 16:25
  • FR-A8TAT

    The output of the FM terminal becomes the current output of the CA. More Details >>

    • No:21060
    • Release Date:2018/08/22 16:25
  • FR-A842

    The inrush current limit circuit is not built in the FR-A842 (inverter unit). It is built in the FR-CC2 (converter unit), which is combined with the FR-A842.... More Details >>

    • No:21059
    • Release Date:2018/08/22 16:25
  • Combination with power factor improving reactor

    It cannot be combined with the power factor improving reactor. (Since the power factor is further improved by the high power factor converter, it is not requ... More Details >>

    • No:21560
    • Release Date:2018/08/22 16:28
  • Using the inverter near a large power supply system

    Use the AC reactor. More Details >>

    • No:21171
    • Release Date:2018/08/22 16:26
  • Installation method

    If multiple line noise filters are wound without clearance between them, the noise reduction effect corresponding to the number of filters cannot be obtained... More Details >>

    • No:22087
    • Release Date:2018/08/22 16:30
  • FR-CV

    The reactor generates a sound during power regeneration, but it is not abnormal. [Reason] The noise from the reactor is caused mainly by the magnetic attract... More Details >>

    • No:21157
    • Release Date:2018/08/22 16:26
  • Replacement of FR-Z100 series

    From Z100 to A520: Use the FR-AAT01 to replace the Z100 with the A520. From Z100 to E520: No attachment is available since E520 is a new series. From Z100 to... More Details >>

    • No:21447
    • Release Date:2018/08/22 16:27
  • Combination with existing inverters

    Since the existing inverters do not have a terminal to connect to the FR-HC, it cannot be connected to them. Use an inverter compatible with the high power f... More Details >>

    • No:21569
    • Release Date:2018/08/22 16:28