  • FR-A842

    The inrush current limit circuit is not built in the FR-A842 (inverter unit). It is built in the FR-CC2 (converter unit), which is combined with the FR-A842.... More Details >>

    • No:21059
    • Release Date:2018/08/22 16:25
  • Brake unit selection

    1. The BU brake unit does not have the fault output.Multiple BU brake units can be connected in parallel.2. Power supply voltage 480 V- What resistance value... More Details >>

    • No:21930
    • Release Date:2018/08/22 16:30
  • FR-B/FR-B3

    Yes. More Details >>

    • No:21063
    • Release Date:2018/08/22 16:25
  • Proper use of AC reactor and DC reactor

    1. ACL has the input power factor of approximately 90% and DCL has the input power factor of approximately 95%. Therefore, DCL has a higher input power facto... More Details >>

    • No:21949
    • Release Date:2018/08/22 16:30
  • Noise filter

    Noise filtering and harmonics suppression are different matters and you need to install the line noise filter (FR-BSF01) against noise and DCL (FR-BEL) again... More Details >>

    • No:21548
    • Release Date:2018/08/22 16:28
  • Replacement of FR-Z100 series

    From Z100 to A520: Use the FR-AAT01 to replace the Z100 with the A520. From Z100 to E520: No attachment is available since E520 is a new series. From Z100 to... More Details >>

    • No:21447
    • Release Date:2018/08/22 16:27
  • FR-A800 and FR-ALF

    Yes, it can. More Details >>

    • No:20806
    • Release Date:2018/08/22 16:24
  • What happens if the supplied reactor and outside box are not used?

    Harmonics cannot be suppressed (controlled) correctly and noise cannot be removed. Be sure to connect the supplied reactor and outside box to the inverter. More Details >>

    • No:21557
    • Release Date:2018/08/22 16:28
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • FR-A8TAT

    Yes, it does. (There are some restrictions. More Details >>

    • No:21082
    • Release Date:2018/08/22 16:25