  • Brake unit selection

    1. The BU brake unit does not have the fault output.Multiple BU brake units can be connected in parallel.2. Power supply voltage 480 V- What resistance value... More Details >>

    • No:21930
    • Release Date:2018/08/22 16:30
  • Influence on noise level

    By using the reactors 1 and 2 as well as the outside box supplied with the high power factor converter, while the noise may increase or decrease depending th... More Details >>

    • No:21559
    • Release Date:2018/08/22 16:28
  • Power supply capacity

    Since the input power factor is improved to approximately 1, the power supply capacity can be reduced to 2/3 to 3/4 of an inverter without a power factor imp... More Details >>

    • No:21556
    • Release Date:2018/08/22 16:28
  • Control cable between high power factor converter and inverter

    Connect the high power factor converter and inverter directly with a control cable, without using a relay. Since a fast-response is required to shut off the ... More Details >>

    • No:21555
    • Release Date:2018/08/22 16:28
  • FR-RC

    Pr.30 = "1" and Pr.70 = "0". More Details >>

    • No:21143
    • Release Date:2018/08/22 16:26
  • FR-BSF-01

    □□□□□□ Year Month (Control number) The last digit of the production year is indicated as the Year, and the Month is indicated by 1 to 9, X (October), Y (Nove... More Details >>

    • No:20982
    • Release Date:2018/08/22 16:25
  • FR-A800 and FR-ALF

    Yes, it can. More Details >>

    • No:20806
    • Release Date:2018/08/22 16:24
  • Phase detection terminal

    The phase detection terminal has been provided with units produced since December 1999. You can identify these units with the serial number "N9Z○○○○○○" or la... More Details >>

    • No:22090
    • Release Date:2018/08/22 16:30
  • Connecting multiple inverters to single high power factor converter

    Up to 6 units. If you connect 7 or more inverters, the permissible output of control signals is exceeded. Be sure to use a high power factor converter with t... More Details >>

    • No:21566
    • Release Date:2018/08/22 16:28
  • Replacement of FR-Z100 series

    From Z100 to A520: Use the FR-AAT01 to replace the Z100 with the A520. From Z100 to E520: No attachment is available since E520 is a new series. From Z100 to... More Details >>

    • No:21447
    • Release Date:2018/08/22 16:27