Check that not only the current but also the various elements of the fuse such as cut-off speed and life are equivalent to those of the recommended product. More Details >>
- No:21153
- Release Date:2018/08/22 16:26
-
Three phases are measured with the CT. The accuracy is ±10 % which is same as the inverter output current. More Details >>
- No:21145
- Release Date:2018/08/22 16:26
-
A reference sine wave signal is generated inside the high power factor converter, and transistors are configured and PWM switching is performed in the conver... More Details >>
- No:21574
- Release Date:2018/08/22 16:28
-
Combination with power factor improving reactor
It cannot be combined with the power factor improving reactor. (Since the power factor is further improved by the high power factor converter, it is not requ... More Details >>
- No:21560
- Release Date:2018/08/22 16:28
-
When the heat sink is outside, since the heat sink and fan are not waterproof, you need to enclose them so that they are not exposed to the spray of water. More Details >>
- No:21435
- Release Date:2018/08/22 16:27
-
Since the input power factor is improved to approximately 1, the power supply capacity can be reduced to 2/3 to 3/4 of an inverter without a power factor imp... More Details >>
- No:21556
- Release Date:2018/08/22 16:28
-
It is not grounded to the enclosure due to the resin coating. More Details >>
- No:21122
- Release Date:2018/08/22 16:26
-
Approximately 2 years when the FR-LU08 is not energized and the real-time clock function is enabled. More Details >>
- No:21084
- Release Date:2018/08/22 16:25
-
Input "0" to the bit not to be sent. More Details >>
- No:20970
- Release Date:2018/08/22 16:25
-
No OL signal is output. More Details >>
- No:20870