FAQ
FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > Options
FAQ
Keyword Search
FAQ within [ Options ]
-
Regenerative driving capability
Continuous 100% regenerative braking torque is available for the rated capacity of the high power factor converter. (The same braking ability of the FR-A201 ... More Details >>
- No:21563
- Release Date:2018/08/22 16:28
-
What happens if the supplied reactor and outside box are not used?
Harmonics cannot be suppressed (controlled) correctly and noise cannot be removed. Be sure to connect the supplied reactor and outside box to the inverter. More Details >>
- No:21557
- Release Date:2018/08/22 16:28
-
Difference between FR-AU01 and AU01A
The major changes from FR-AU01 to FR-AU01A include 1. Case material and 2. Lead wire terminal process method. The FR-AU01A has a backward compatibility with ... More Details >>
- No:21452
- Release Date:2018/08/22 16:27
-
It is available. Insulate the raised wiring of T-phase. More Details >>
- No:21177
- Release Date:2018/08/22 16:26
-
The reactor generates a sound during power regeneration, but it is not abnormal. [Reason] The noise from the reactor is caused mainly by the magnetic attract... More Details >>
- No:21157
- Release Date:2018/08/22 16:26
-
Since the FR-HC2 switches the TRM according to the power supply phase, it has a circuit that detects the power supply phase. "A phase is confirmed" when the ... More Details >>
- No:21154
- Release Date:2018/08/22 16:26
-
It controls the charging current immediately after the power is ON. (as a MC (magnetic contactor) for the charging current limit circuit, etc) More Details >>
- No:21149
- Release Date:2018/08/22 16:26
-
It is not available and "Err" is displayed. When the FR-HC2 dedicated DU (FR-DU07-CNV) is installed to the inverter, "Err" is displayed as well. The FR-PU07 ... More Details >>
- No:21148
- Release Date:2018/08/22 16:26
-
It is 0.88 mm2 (AWG18), and 0.3 mm2 (AWG24) for the thermostat. More Details >>
- No:21147
- Release Date:2018/08/22 16:26
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
41-50 of Total 129