FAQ


FAQAbout Products
- FAQ > Drive Products > Inverters-FREQROL > Options
FAQ
Keyword Search
FAQ within [ Options ]
-
It bypasses (removes) high-frequency current due to switching that is output by the FR-HC2 to prevent it from being flown into the power supply system as a f... More Details >>
- No:21152
- Release Date:2018/08/22 16:26
-
Using the inverter near a large power supply system
Use the AC reactor. More Details >>
- No:21171
- Release Date:2018/08/22 16:26
-
Installing reactor for suppressing harmonics
You can connect multiple inverters to a single reactor. In this case, the load seems to be light from the reactor unless all of the inverters are rotating an... More Details >>
- No:21410
- Release Date:2018/08/22 16:27
-
We offer DC reactors from 0.4K and you can use it. You can use FR-BIF, FR-BSF, and FR-BEL together. More Details >>
- No:21461
- Release Date:2018/08/22 16:27
-
Difference between use with A100 and other types
Similarly to the FR-A200 and A500, four or more filters should be used also for the FR-A100. In short, it is OK if the wire penetrates the filter four times... More Details >>
- No:21468
- Release Date:2018/08/22 16:27
-
What is the replacement of the FR-BOL?
We do not offer a replacement product for the FR-BOL (noise reduction reactor). Since the FR-A100E is a low-noise type inverter, the motor noise is suppresse... More Details >>
- No:21500
- Release Date:2018/08/22 16:27
-
If all inverters are in regenerative operation, the regenerative power is regenerated to the power supply. If one of the inverters is power driving, the rege... More Details >>
- No:21564
- Release Date:2018/08/22 16:28
-
The high power factor converter itself is almost same size as general-purpose inverter with the same capacity (FREQROL-A200 series), however, an additional s... More Details >>
- No:21571
- Release Date:2018/08/22 16:28
-
To almost "1". (With load factor of 100%) More Details >>
- No:21577
- Release Date:2018/08/22 16:28
-
EMC compliant filter terminal cover
The SF1258 has the terminal cover.Although the SF1259 to SF1263 do not have the terminal covers and their terminals are bare, rubber tubes to cover them are ... More Details >>
- No:21956
- Release Date:2018/08/22 16:30