  • FR-HC2

    The power of MC1 is supplied from the terminals across R2 and S2 of the outside box. Either phase of R2 or S2 may be lost. More Details >>

    • No:21146
    • Release Date:2018/08/22 16:26
  • Difference between use with A100 and other types

    Similarly to the FR-A200 and A500, four or more filters should be used also for the FR-A100.  In short, it is OK if the wire penetrates the filter four times... More Details >>

    • No:21468
    • Release Date:2018/08/22 16:27
  • Control wire of FR-HC RDY signal

    The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>

    • No:22017
    • Release Date:2018/08/22 16:30
  • FR-HC2

    It bypasses (removes) high-frequency current due to switching that is output by the FR-HC2 to prevent it from being flown into the power supply system as a f... More Details >>

    • No:21152
    • Release Date:2018/08/22 16:26
  • What is the replacement of the FR-BOL?

    We do not offer a replacement product for the FR-BOL (noise reduction reactor). Since the FR-A100E is a low-noise type inverter, the motor noise is suppresse... More Details >>

    • No:21500
    • Release Date:2018/08/22 16:27
  • FR-PU07BB

    Because the internal reset processing is performed when the power supply is turned OFF, the fault state cannot be held. The details of the faults are saved i... More Details >>

    • No:20942
    • Release Date:2018/08/22 16:25
  • FR-E700-SC

    Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>

    • No:21130
    • Release Date:2018/08/22 16:26
  • Combination of the FR-F800 and FR-A8TAT

    Yes, it can. For the capacity of 37K or more, use the included bracket for installation. More Details >>

    • No:20841
    • Release Date:2018/08/22 16:24
  • FR-A842

    The inrush current limit circuit is not built in the FR-A842 (inverter unit). It is built in the FR-CC2 (converter unit), which is combined with the FR-A842.... More Details >>

    • No:21059
    • Release Date:2018/08/22 16:25
  • Selection method of the FR-ABR

    The multiple rating is adopted from the FR-A800 series and the motor and the inverter are no longer one-to-one. Thus, considering the combination that the mo... More Details >>

    • No:20846
    • Release Date:2018/08/22 16:24