  • Control terminal block

    It is available if the option FR-A8TAT (Control circuit terminal block intercompatibility attachment) is installed. (Some functions have restrictions. For th... More Details >>

    • No:21087
    • Release Date:2018/08/22 16:25
  • What is the replacement of the FR-BOL?

    We do not offer a replacement product for the FR-BOL (noise reduction reactor). Since the FR-A100E is a low-noise type inverter, the motor noise is suppresse... More Details >>

    • No:21500
    • Release Date:2018/08/22 16:27
  • Regenerative power flow

    If all inverters are in regenerative operation, the regenerative power is regenerated to the power supply. If one of the inverters is power driving, the rege... More Details >>

    • No:21564
    • Release Date:2018/08/22 16:28
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • FR-BMF

    The inverter may be broken due to the temperature rise of the internal parts. More Details >>

    • No:21140
    • Release Date:2018/08/22 16:26
  • FR-BSF-01

    □□□□□□ Year Month (Control number) The last digit of the production year is indicated as the Year, and the Month is indicated by 1 to 9, X (October), Y (Nove... More Details >>

    • No:20982
    • Release Date:2018/08/22 16:25
  • Installation of the FR-PA07

    Yes, because the same enclosure cut dimensions is adopted. More Details >>

    • No:20866
    • Release Date:2018/08/22 16:24
  • FR-CV

    Use the FR-HC to suppress harmonics. It also supports power supply regenerative driving.The FR-CV and FR-RC are both power supply regeneration units.The diff... More Details >>

    • No:22038
    • Release Date:2018/08/22 16:30
  • Using a higher grade power factor improving reactor

    Using a reactor under a load lighter than the rated capacity slightly spoils its effect in improving the power factor.Therefore, you should use a reactor wit... More Details >>

    • No:21935
    • Release Date:2018/08/22 16:30
  • Size

    The high power factor converter itself is almost same size as general-purpose inverter with the same capacity (FREQROL-A200 series), however, an additional s... More Details >>

    • No:21571
    • Release Date:2018/08/22 16:28