  • FR-RC

    Pr.30 = "1" and Pr.70 = "0". More Details >>

    • No:21143
    • Release Date:2018/08/22 16:26
  • Proper use of AC reactor and DC reactor

    1. ACL has the input power factor of approximately 90% and DCL has the input power factor of approximately 95%. Therefore, DCL has a higher input power facto... More Details >>

    • No:21949
    • Release Date:2018/08/22 16:30
  • Power factor improving reactor

    Your understanding about the AC and DC reactors is correct. For the harmonics suppression effect obtained by using both types of reactors, refer to the table... More Details >>

    • No:21994
    • Release Date:2018/08/22 16:30
  • Control terminal block

    It is available if the option FR-A8TAT (Control circuit terminal block intercompatibility attachment) is installed. (Some functions have restrictions. For th... More Details >>

    • No:21087
    • Release Date:2018/08/22 16:25
  • FR-RC selection

    1. The 100% braking torque means the 100% motor rated torque. Do not consider the continuous regenerative driving based on the braking torque. Consider the r... More Details >>

    • No:22023
    • Release Date:2018/08/22 16:30
  • Using a higher grade power factor improving reactor

    Using a reactor under a load lighter than the rated capacity slightly spoils its effect in improving the power factor.Therefore, you should use a reactor wit... More Details >>

    • No:21935
    • Release Date:2018/08/22 16:30
  • FR-BSF-01

    □□□□□□ Year Month (Control number) The last digit of the production year is indicated as the Year, and the Month is indicated by 1 to 9, X (October), Y (Nove... More Details >>

    • No:20982
    • Release Date:2018/08/22 16:25
  • SC type (with an encoder) of the SF-PR

    Use the FR-V7CBL5/15/30 as using it with the vector motor SF-V5RU connection. More Details >>

    • No:20867
    • Release Date:2018/08/22 16:24
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • DC reactor

    It can be used since the specifications are the same. Note that the warranty period and expected lifespan for the A700/F700P are inherited. More Details >>